GRP Moulded Grating ISO 50 SWL (26 x 26)
Heavy duty, mesh 26 x 26 mm
Span width (mm) |
Concentrated load (kg) |
Safety factor |
Distributed load (kg/m2) |
Safety factor |
|
---|---|---|---|---|---|
300 | 13.474 | 2 x F | 71.866 | 3 x q | |
450 | 5.948 | 3 x F | 21.148 | 4 x q | |
600 | 3.334 | 4 x F | 8.891 | 5 x q | |
750 | 2.129 | 5 x F | 4.543 | 7 x q | |
900 | 1.476 | 6 x F | 2.625 | 8 x q | |
1.000 | 1.195 | 7 x F | 1.912 | 9 x q | |
1.200 | 829 | 8 x F | 1.105 | 10 x q | |
1.300 | 706 | 8 x F | 869 | 10 x q | |
1.400 | 608 | 8 x F | 695 | 10 x q | |
1.500 | 530 | 8 x F | 565 | 10 x q | |
The loads were determined at a bending of L/125. The bending L/125 corresponds to 0.75% bending of the span width (Bending f=L/125; L= span width). The application-specific suitability is to be tested individually. |
L (mm) | B (mm) | kg/m2 |
---|---|---|
4.000 | 1.220 | 42 |
1.988 | 998 | 42 |
Other dimensions are available on request.
This post is also available in: Swedish Norwegian Bokmål