ISO 50 SWL (26 x 26)

GRP-gitterriste ISO 50 SWL (26 x 26)

Heavy duty, mesh 26 x 26 mm

Span width
(mm)
Concentrated
load (kg)
Safety
factor
Distributed
load (kg/m2)
Safety
factor
300 13.474 2 x F 71.866 3 x q
450 5.948 3 x F 21.148 4 x q
600 3.334 4 x F 8.891 5 x q
750 2.129 5 x F 4.543 7 x q
900 1.476 6 x F 2.625 8 x q
1.000 1.195 7 x F 1.912 9 x q
1.200 829 8 x F 1.105 10 x q
1.300 706 8 x F 869 10 x q
1.400 608 8 x F 695 10 x q
1.500 530 8 x F 565 10 x q
The loads were determined at a bending of L/125. The bending L/125 corresponds to 0.75% bending of the span width (Bending f=L/125; L= span width). The application-specific suitability is to be tested individually.
L (mm) B (mm) kg/m2
4.000 1.220 42
1.988 998 42

Other dimensions are available on request.