GRP-gitterriste ISO 25 micro (13 x 13)
Mesh 13 x 13 mm
Span width (mm) |
Concentrated load (kg) |
Safety factor |
Distributed load (kg/m2) |
Safety factor |
---|---|---|---|---|
300 | 1.030 | 2 x F | 5,400 | 3 x q |
450 | 450 | 3 x F | 1.610 | 4 x q |
600 | 255 | 4 x F | 680 | 5 x q |
750 | 163 | 5 x F | 346 | 7 x q |
900 | 113 | 6 x F | 200 | 8 x q |
1.000 | 91 | 7 x F | 146 | 9 x q |
1.200 | 64 | 8 x F | 85 | 10 x q |
The loads were determined at a bending of L/125. The bending L/125 corresponds to 0.75% bending of the span width (Bending f=L/125; L=span width). The application-specific suitability is to be tested individually. |
L (mm) | B (mm) | kg/m2 |
---|---|---|
4.000 | 1.220 | 16,8 |
1.983 | 995 | 16,8 |
Other dimensions are available on request.